How does Loxone compare to Comfort or Fibaro?

Hi All, I appreciate this group is likely to be pro Loxone but I would like your thoughts. I have been a home automation dabbler for many years starting with X10 20 years ago. I have a Comfort gen1...

View Article


Evohome boiler control bdr91 comms issue

Hi IÂ’m having intermittent comms issue with the bdr 91 controlling the boiler, rf check gives signal of 5 and itÂ’s located in boiler cupboard 0.5m from the boiler, the problem I think is due to the...

View Article


OpenTherm & Intergas Xclusive Minimum CH Flow Temp

Just wondering what others have configured when OpenTherm demand is very low? The Xclusive has a parameter (P057) "Response for OpenTherm room thermostat" with the following options: 0 = do not respond...

View Article

Evohome random overrides

Every now and then I'll find the heating is blasting in some room that it shouldn't be. If I look at the EvoHome controller it'll show me an override is set. It's hard to track down but I am fairly...

View Article

Heating control using Shelly devices

Has any one used Shelly devices to control their heating system and if so what did you use.

View Article


EvoHome opentherm with dual cascaded boilers config

Is anyone using evoHome with twin opentherm boilers in a cascade setup? Elsewhere on this forum it says to buy two opentherm controllers for EvoHome and bind both to the same system. Is that correct...

View Article

Image may be NSFW.
Clik here to view.

Best way to use 3 motorised valves with evohome?

Hi I'm looking for some help with the design of my evohome system. My system looks like this: evohome diagram.jpg You can see I have 3 motorised valves plumbed in parallel (hot water, underfloor...

View Article

Evohome not behaving as expected

Hi I have a new installation of Evohome which I am having trouble getting to work consistently. The system is an oil fired boiler, with a ATP921R3100 Controller, a BDR91 Wireless Relay Box, a water...

View Article


Evohome and MVHR

I have Honeywell Evohome controlling my central heating. 11 zones and 16 TRVs. Been in close to four years now and happy with it regarding controlling temperatures. However, we do get a bit of...

View Article


App failure

Anybody else experiencing an app + web site failure today? I checked the app on my mobile and the readings did not make sense to what they should. The same on other devices and also on the web site...

View Article

BDR91 Fault

I've got a BDR91 installed as a zone value relay for my Evohome. It's been successfully working for around 18months, however, it's suddenly stopped working. Evohome reports a comms failure. The device...

View Article

Evotouch showing hourglass on 6 out of 8 zones

Hi there, I have this evotouch system I have installed myself with evotouch, BDR91 and 8 x HR92 controllers (since many years now ...) , but this is the first time I see 6 hourglasses on the evotouch...

View Article

Can an Evohome system be introduced in stages?

My wife and I are empty-nesters living in a detached 5-bedroom house, with traditional heating and indirect hot water (Potterton Profile 80e balanced flue gas boiler, hot water cylinder and cold water...

View Article


Evohome, Opentherm R8810A1018 with RFBee UARTBee

Hi Any help with the following would be much appreciated. I have Evohome running 8 rads 7 of which have HR92's fitted. I have recently upgraded my boiler to an Ideal Vougue Max 32Kw Combi and replaced...

View Article

Image may be NSFW.
Clik here to view.

Evohome TRV Valve Adapters

Hi, Hopefully someone can help. DIYer. I have just purchased 4 HR92s to add into our basic one zone set up. Each of the rads currently have different TRV bodies on and so I wondered which adapters I...

View Article


Homebrew Enhanced Cold Weather Boost

Hi all, May or may not be of interest but I live in an oldish house that isn't as efficient as it could be. I have implemented cold weather boost which is ok but I've found that it doesn't work too...

View Article

Evohome showing faults on nearly all actuators

I noticed a couple of rooms were showing "actuator comms fault" earlier today. I figured maybe a battery issue but the ones I checked seemed fine. Now, virtually ALL my actuators are showing faults -...

View Article


battery eliminators?

anyone used battery eliminators to power HR92's? I've got one that's in a really awkward spot for battery changing, but running a wire to it for permanent power would not be too difficult. tempted to...

View Article

Problem binding Evohome HR92

I took delivery of an Evohome system this morning and decided to start by setting a basic single zone configuration on the central controller, bound to a single HR92. No BDR91 has been installed so far...

View Article

HR92 misbehaving

If the position reported is <20% and the radiator is still heating you probably have a physical problem with the valve body (seizing up/stiff) or it is not fully compatible with the HR92 in terms of...

View Article